Kia Clarus/Credos

1995-2001 of release

Repair and car operation



KIA Klarus
1.1. Periodicity of maintenance
+ 2. FE DOHC engines and Т8 DOHC
+ 3. Greasing system
+ 4. Cooling system
+ 5. Power supply system and release
+ 6. Fuel system
+ 7. Ignition system
+ 8. Coupling
+ 9. Mechanical transmission
+ 10. АКП G4A–EL
+ 11. АКП 50–40 LE
+ 12. Axes and power shafts
+ 13. Steering
+ 14. Wheels and tires
+ 15. Suspension bracket
+ 16. Body
- 17. Central air
   17.1. Specifications
   17.2. Check of drives of central air
   17.3. Connection of pipelines
   17.4. Quick disconnect connecting couplings
   17.5. Check of elements of central air located in salon of the car
   17.6. Removal and compressor installation
   17.7. Drive of management of modes
   17.8. Mixing drive
   17.9. Air inlet drive
   17.10. Channel sensor
   17.11. Compressor
   17.12. Magnetic coupling
   17.13. Two-regime relay of pressure
   17.14. Coolant (R–134A)
   17.15. Main data on service of system of cooling
   17.16. Search and elimination of malfunctions
+ 18. Electric equipment
+ 19. Brake system
+ 20. Electric circuits






17.1. Specifications

GENERAL INFORMATION

Position
Technical characteristics
FE DOHC
Т8 DOHC
Cooling the maximum cooling ability
4200 kcal/h
air stream LO–HI (weak-strong)
1 80–490 мэ / h
consumer flax and е capacities electric motor of the main fan
260 W (12 In)
Heating the maximum cooling ability
3900 kcal/h
air stream LO–HI (weak-strong)
130–370 мэ / h
capacity consumption electric motor of the main fan
220 W (12 In)
Knots of the air conditioner compressor Type
lopastny rotational (DKV–14C)
FX–15 with a distortion of the planes
target characteristic
140,5 смэ / turn
154 cm3/turns
oil
EXL 200PG (200 cm3)
PQ (140–1 60 cm3)
magnetic coupling capacity consumption
Max. 45 W (12 In)
Max. 41 W (12 In)
moment
minute of 4,0 kg • m
condenser type
RR type
possibilities
minute 1100kkal/h
dehumidifier of a broad tank vlagopoglotitel
ХН9
evaporator type
laminatny type
broad valve
external type with equal pressure
Thermorelay
ВЫКЛ: 2,5°С DIFFERENCE: 4°С
relay of high / low pressure
Adjustment of a high pressure it is SWITCHED OFF: 32 kg/cm2 (log huts.) DIFFERENCE: 6 kg/cm2 (log huts.) Adjustment of low pressure it is SWITCHED OFF: 2 kg/cm2 (log huts.) DIFFERENCE: 0,25 kg/cm2 (log huts.)
Heater components heater core
aluminum edges and tubes (plastic capacity)
method of management
method of mixing of warmed-up air
Control system knots control system components Block of automatic control
Drive of a shutter of mixing of air
Shutter drive
Exit of management of modes
Drive of a shutter of management retsirkuliruyemym/fresh air
Power transistor
Cooling method
compression паров
Coolant
R–134a (700±30r)