Kia Clarus/Credos

1995-2001 of release

Repair and car operation



KIA Klarus
1.1. Periodicity of maintenance
+ 2. FE DOHC engines and Т8 DOHC
+ 3. Greasing system
+ 4. Cooling system
+ 5. Power supply system and release
+ 6. Fuel system
+ 7. Ignition system
+ 8. Coupling
+ 9. Mechanical transmission
+ 10. АКП G4A–EL
+ 11. АКП 50–40 LE
+ 12. Axes and power shafts
+ 13. Steering
+ 14. Wheels and tires
+ 15. Suspension bracket
+ 16. Body
- 17. Central air
   17.1. Specifications
   17.2. Check of drives of central air
   17.3. Connection of pipelines
   17.4. Quick disconnect connecting couplings
   17.5. Check of elements of central air located in salon of the car
   17.6. Removal and compressor installation
   17.7. Drive of management of modes
   17.8. Mixing drive
   17.9. Air inlet drive
   17.10. Channel sensor
   17.11. Compressor
   17.12. Magnetic coupling
   17.13. Two-regime relay of pressure
   17.14. Coolant (R–134A)
   17.15. Main data on service of system of cooling
   17.16. Search and elimination of malfunctions
+ 18. Electric equipment
+ 19. Brake system
+ 20. Electric circuits






17.8. Mixing drive

GENERAL INFORMATION

Check of a drive of mixing

The drive receives signals from the block of automatic control and joins for opening of a shutter of mixing. In this drive the potentiometer defining the provision of a shutter of mixing is established.

1. Potentiometer

The potentiometer is the resistor established on the printed-circuit board of a drive. According to target speed it defines the provision of a shutter of mixing as the tension relation on mobile contact Е1 to basic tension Е and sends the signal on the block of automatic control as a feedback signal.

2. Drive work

If signals from an exit of the block of automatic control are such as are described below, the electric motor established in a drive will turn on.

Sliding contacts rotate, being rigidly fixed on day off to an electric motor shaft, and it stops at hit of sliding contact on a plate of contacts And or Century.

At shutdown of a target signal of the block of automatic control the electric motor stops irrespective of the provision of contact.

Installation

PERFORMANCE ORDER
1. Check, whether will earn the electric motor after giving (+) on contact 4 and (–) on contact 5.
Check also change of the direction of its rotation on opposite at connection upside-down.
2. At malfunction of the electric motor replace it.