1. Establish the valve of switching of transfer. Inhaling moment: 58,8–68,6 N • m |
Prevention Clear a contact surface of a lateral casing of ATF and the hermetic remains. Put hermetic from the interior of openings for bolts of fastening of a casing, without interrupting a strip of the put hermetic. |
| |
2. Put hermetic (three bond 1281B) on a lateral casing. |
Prevention The strip of hermetic should have width of 1,0-1,5 mm. The knot is subject to assembly not later, than through 5 mines after hermetic drawing.
|
3. Establish a lateral casing and fix bolts. Inhaling moment: 20–29 N • m |
4. Establish new laying and screw a drain stopper. Inhaling moment: 24–55 N • m |
5. Fill in transmission ATF liquid and check on absence of leaks from a lateral casing. |