Code number | Faulty knot | Self-diagnostics |
Fault tolerance |
12 | Sensor of provision of a butterfly valve | If porosity of impulses is lower than 5,0 % or 94 % are higher or the control signal of the engine is not found. | Alarm mode |
55 | Sensor speeds (exit) | If among 3000 impulses of a target signal of speed there are no impulses of giving of an entrance signal of speed. | Alarm mode |
60 | Valve of switching of transfer No. 1 | If at the switched-off exit of a chain of a drive of the valve the monitor defines it as included, and it joins during 8 movements of switching of transfer. | Alarm mode |
61 | Valve of switching of transfer No. 2 | Alarm mode |
63 | Blocking valve | If at the included exit of a chain of a drive of the valve the monitor defines it as switched off | Alarm mode |
64 | The valve of regulation of pressure in the line | For a high voltage on o exit If the maximum tension is lower than 1 V.Dlya of a low voltage on o exit If the low voltage is higher 50 мВ. | Alarm mode |
65 | Moment regulator | If it is revealed that a control signal of a regulator of the moment high or low. | Alarm mode |
66 | Sensor speeds (entrance) | If among 5000 impulses of an entrance signal of speed there are no impulses of giving of a target signal of speed. | Alarm mode |